HPLC/ GC
Analytical Cell ESA Modell 5010
gebraucht
Model 5010A provides excellent long-term stability and day-to-day reproducibility. The large surface area of the coulometric electrodes permits long periods of operation without a reduction in signal.
Preis: 400,-€
WATERS REAGENT MANAGER
LAB ALLIANCE SERIES III DIGITAL HPLC PUMP
gebraucht
Preis: 750,-€
Dionex Gina ASI-100 (Thermo Scintific)
gebraucht
Lieferung inklusive Netzstecker, kein weiteres Zubehör enthalten
Bedienungsanleitung unter:
http://www.dionex.com/en-us/webdocs/4675-ASI100_OI_E_V2_0.pdf
Preis: 1800,-€
hplc station famos ultimate
Komplette HPLC-Anlage bestehend aus Detektor , Pumpe und Probenaufgabe
gebraucht
Preis: 3000,-€
Hewlett Packard HPLC-System der Serie 1090 L/M
gebraucht
INV-Nr 266183 Seril 3533A05237 Made in USA
Preis: 2000,-€
HP GPIB Karte ISA 82335-60001 REV F HP-IB Schnittstellenkarte
neues Produkt
Preis: 200,-€
BESTA Motorventil Typ:N 10 bar
gebraucht
12 Wegeventil
Preis: 230,-€
aus PTFE sind chemisch Inert, haben null totvolumen und sind geeignet zur Probenentnahme und Probenaufgabe sowie zum Umschalten verschiedener Flüssigkeitsströme.
Arbeitsweise:
Der Rotor aus PCTFE wird durch drehen um 60º in die gewünschte Position gebracht.
Je nach Rotorausführung erhält man die verschiedenen Flußdiagramme.
Anschluss:
Innengewinde ¼"
Ventil | Bohrung | Flußdiagramm | Druck | Kat.Nr. |
|
||||
12- Wege Ventil 12-Wege Ventil |
0,8mm
|
|
10 bar
|
11140
|
HAMILTON MVP 36798 MODULARE VENTILSTELLUNGSREGLER
neu/ unbenutzt
Preis: 450,-€
MVP Technical Specifications
Description | Serial (RS-232) MVP | Digital (TTL) MVP | ||||||||||
Rotational Speed | 20 RPM (3 seconds full revolution) | 20 RPM (3 seconds full revolution) | ||||||||||
Power Requirements |
|
|
||||||||||
Communications Interface | RS-232 at 1200, 2400, 4800, and 9600 Baud | TTL, 8 inputs and 8 outputs | ||||||||||
Communication Language |
|
Binary, Discrete, and Sequential | ||||||||||
Weight | 1.15 lbs. (0.25 kg) without power adapter | 1.15 lbs. (0.25 kg) without power adapter | ||||||||||
Height | 4.4 in (11.2 cm) | 4.4 in (11.2 cm) | ||||||||||
Width | 2.4 in (6.1 cm) | 2.4 in (6.1 cm) | ||||||||||
Depth | 4.23 in (10.7 cm) without valve | 4.62 in (11.7 cm) without valve | ||||||||||
Valve Type | HV "Snap-in and Snap-out" | HV "Snap-in and Snap-out" | ||||||||||
Fluid Path | PTFE and Kel-F® (CTFE) materials | PTFE and Kel-F® (CTFE) materials |
BIO-RAD ECONO BUFFER SELECTOR EV1 / EVI
gebraucht
Preis: 300,-€
Nelson Interface Serie 900
gebraucht
Für Gebrauch zusammen mit LC oder GC
Schnittstellen serial-Rack Vial-Detector-Relais-GPIB
100-220VAC, 50-60Hz, 130mA
Gehäuse (T)x(H)x(B): 32 x 23,5 x 11,3 cm
Preis: 300,-€
BIO-RAD ECONO GRADIENT MONITOR EG1 / EGI
gebraucht
Preis: 300,-€
QUMA QHSS-111 Headspacesampler
gebraucht
Preis: 1500,-€
Systembeschreibung
Automatischer Probengeber für 111 Proben (20 ml) nach der "Head Space"-Technik. Optimiert für schnelle Analytik mit konstanter Inkubationszeit aller Proben. Softwaresteuerung für den QHSS-111 ist lieferbar.
Optimiertes inertes Injektionssystem (auch für polare Hochsieder).
Technische Daten:
20 ml Vials mit Schraub- und Bördelkappen nutzbar !
111 Proben 20 ml HSS Vials
Inkubationsofen für 12 Proben
Proben von 40 °C bis 200 °C temperierbar
MHE mit max. 250 Schritten,Multiinjektion;
Sample-Loop oder Druckinjektion lieferbar
Leicht zugänglicher Inkubationsofen
Mit "Galaxie" Software (Varian) komplett fernbedienbar
Maße ca. Breite X Höhe X Tiefe 34 X 40 X 56 cm³
WATERS 994 DAD
PROGRAMMABLE PHOTODIODE ARRAY DEDECTOR
gebraucht
Preis: 980,-€
Einstellbar ist die Durchflussrate von 0,00 - 5,00 ml / min. und der Druck von 1 - 400 bar.
Die HPLC Pumpe kann auch stand-alone genutzt und mit anderen Detektoren, Ventilen und Co. genutzt bzw. kombiniert werden.
700,00 €
Endpreis, zzgl. Versandkosten
Versandkostenfrei in folgende Länder: Mehr anzeigen Weniger anzeigen
Siemens Advia 1650 (früher Bayer Diagnostics) mit aktuellem Wartungsnachweis
Laborgerät Advia 1650 in der Ausführung mit Probenteller (kein Rackhandler),
PC /-Steuereinheit und diverse Originalersatzteile.
Das Gerät kann nach Terminabsprache besichtigt werden.Nachweise über kontinuierliche Wartungen liegen vor. Ebenso das Zertifikat der Außerbetriebnahme sowie Dekontamination.
HPLC Gradientenpumpe Merck Hitachi L6200
gebraucht
Preis auf Anfrage
Merck Hitachi 655A Variable Wavelength UV Monitor
gebraucht
Preis: 650,-€
Agilent / HP1050 UV-Detektor
gebraucht
Handbuch/ Manual Vorhanden
Preis: 1100,-€
About the Detector
The 1050 Variable Wavelength Detector (VWD) is a detector of the modular type liquid chromatograph 1050 Series. This is a standalone grating/photodiode type general purpose detector. The performance and features match the requirements of the routine analysis and QC/QA analysis. The 1050 VWD is a standard size detector of 1050 modular type LC series and can be build up with other LC modules, such as pump and automatic sampler. Since it is standalone type, it can be also used as an ordinary LC detector. It has a functional keyboard and 16-character fluorescent display which provides you easy operation.
Metrohm 697 IC Pump
guter optischer Zustand
defektes Display
Handbuch/ Manual vorhanden
Preis: 300,-€
Melz RI-Detector LCD 312
gebraucht
Preisauf Anfrage
CRYSTAL CE SYSTEM ATI UNICAN 310
gebraucht
ohne Zubehör
Preis: 1000,-€
Product Description:
The modular Thermo Capillary Electrophoresis[TM] Crystal CE System joins the Thermo/ATI Unicam Crystal 1000 CE Conductivity Detector with the Thermo 310 Autosampler and HVPS high voltage power supply to provide separations for analyses based on differences in molecular size, shape and charge, as well as entangled polymer solutions and selected stationary phases used
in chromatography.
Crystal 1000 Analyzer (Detector)
Detection volume of less than 3 nanoliters permits more sensitive detection of small molecular weight ions than do conventional indirect detection methodologies
ConTip[TM] and ConCap[TM] fused silica capillaries are provided with
quick finger tight connectors
Provides a suite of sensors: Interchangeable ConTip[TM] conductivity sensor; Low Electrolyte Reservoir; Alert/Shutdown Sensor; High-voltage safety interlock sensors
Between analyses rinses Auto Detector Cell
Includes Temperature Controlled Detector Cell (above ambient to 42 degrees C)
Provides semi-automatic cell purge routine for electrolyte conversion
Convenient front-panel includes push button electrolyte dispenser, four detector methods memory/recall
2-Lift system Prince Autosampler
Dynamic Compression Injection (DCI) generates and applies a range of positive and negative pressures with controlled ramping that lead to reliable and reproducible results; allows control, programming and application of positive and negative injection pressures without the use of external sources and valve even during electromigration of analytes
Electrokinetic injection controls ramping in either voltage or current mode in the automated injection system
Maintains application environment, eliminating variation in pressure and voltage during the injection process; controls capillary temperature by recycling airflow that is thermostatically regulated by Peltier elements, thus eliminating outside temperature fluctuations
High Pressure for CEC and CGE eliminates the need for an external pressure source
Carrousel provides accommodation for 30-48 sample/buffer vials and Peltier control of temperature to protect samples from evaporation and degeneration
Compatible with other detectors (e.g., UV/VIS, Fluorescence, Diode Array, Mass Spectrometer, and uLIF)
PrinCE-HVPS high voltage power supply
Enables programmable polarity-switching feature that can either be pre-programmed or activated during injection or run situations, as well as upslope, downslope, and in-run voltages and pressure
HPLC Mischer/ LC Mixer High Pressure Mixing Chamber
neu
1,00 ml
Preis: 250,-€
SSI Scintific Systems Puls Damper
Model LP-21
neu
Preis: 300,-€
Scientific Systems inc (SSI) LP-21 Diaphragm-type pulse damper.
The Model LP-21 LO-Pulse pulse damper is a patented wide dynamic range pulse damper designed for use with single piston reciprocating HPLC pumps.
It uses 1/4-28 SSI-type fittings and operates up to 6000 psi.
The noise level in the detector resulting from pump pulsations can significantly affect precision in qualification and the detection limit of trace components. The LO-Pulse pulse damper smooths pump pulsations and maintains constant flow in flow sensitive detectors.
The LO-Pulse pulse damper reduces pulsations by compressing a fluid held within the bottom cavity of the unit. This fluid is isolated from the LC mobile phase by a durable but flexible inert diaphragm. As the HPLC system pressure increases, fluid in the bottom chamber is compressed. When the LC pump piston is retracting, the compressed fluid expands maintaining system pressure and, more importantly, keeps the mobile phase flowing at a constant rate. When the system pressure is at its maximum allowable pressure (6000 psi), the volume of mobile phase in the LO-Pulse is only 0.9mL.
Diasys Super G Glukose Analyser
gebraucht
Preis: 600,-€
CMA Microdialysis CMA/200 refrigerated Microsampler
gebraucht
Preis auf Anfrage
Kontron HPLC Hochdruck Pumpe 422
Flußbereich: 0,01 bis 2,00 ml
Die Pumpe benötigt neue Kolben und eine Feder, ansonsten funktionstüchtig.
Preis auf Anfrage
Eppendorf EVA-Master (66001 P 00064) - Steuergerät - Ansteuerung für Sampler
gebraucht
Preis: 200,-€
Probengeber GINA 160
Injektionsautomat von Gynkotek
gebraucht
Preis auf Anfrage
Dionex Autosampler ASM-3
gebraucht
Preis auf Anfrage
Glassäule analytischer und präparativer Chromatographie
Hersteller: W.Krannich
Länge: 106,00 cm
Bettlänge: 100,00 cm
Bettbreite: 5,00 cm
Kühlung durch äußeren Wasser-Kühlmantel.
Die Säule hat einen kleinen Glasschaden am Kühlwassereinlauf,
was die Funktion nicht beeinträchtigt.
Preis: 500,-€
Pharmacia LKB REC 1 Kipp & Zonen Linienschreiber Flachbettschreiber Labor
gebraucht
Preis auf Anfrage
LABLOGIC IN/US MODEL 4 BETA-RAM RHPLC DETECTOR
gebraucht
Preis: 1200,-€
Whatever challenge your analysis presents, the β-RAM model 4 has a configuration to suit you. Coupled with the industry standard Laura™ radiochromatography data system the β-RAM model 4 leads the way for radiochromatographers. Specially designed flow cells in volumes ranging from 5ul give superb performance under even the most demanding conditions. The β-RAM range has always offered the lowest background and the model 4 improves this even further. The model 4 also features sub-second update times to ensure the greatest accuracy with the tightest peaks. Low dead volume fittings, tubing and mixing components optimized for low flow rates ensure optimum peak shape and definition.
Gamma/l Dosierpumpe Pumpe
gebraucht
Preis auf Anfrage
Analytical Cell ESA Modell 5010
gebraucht
Model 5010A provides excellent long-term stability and day-to-day reproducibility. The large surface area of the coulometric electrodes permits long periods of operation without a reduction in signal.
Preis: 400,-€